Spesifikasi COM 1600

 COM-1600 Potentiometric Titrator Specifications
 COM-1600 Standard Specifications
 
Item Specifications
Titration methods Potentiometric titration, Polarization titration,
Photometric titration, Conductometric titration.
Standard: three inputs of potentiometric titration. (Other titration methods each require a proper measurement unit (option).)
Measurement range pH: 0 to 14 with automatic/manual temperature
compensation 
Potential: -2000 to +2000 mV
Temperature: 0 to 100 
End-point detection
method
Learn titration, inflection-point detection, set point detection, inflection-point/set-point detection, cross-point (F, B, V1, V2) detection, dispensing (pH, mL), petroleum product neutrali zation value mode (1, 2), pH measurement, pH Stat, pKa measurement, and calculation.
Number of end-points Learn titration: up to 5 end-points, with linked
CONDITIONs: up to 3 end-points.
Display screen Color graphics liquid crystal display
SAMPLE No. SAMPLE No.: 2 digits, ID code: 16 digits of alphabetical or numerical characters
MASTER files Titration run files: 30
Number of linked CONDITION files: 7 (up to 3 titration files)
CONDITION files Titration parameter files: 30 (Method (For each end point detection), CONSTANT parameter (Concentration calculation constant parameter), Control mode files)
Control mode files Standard files: 30
Petroleum product neutralization value files: 30
Manufacturer preinstalled modes (0 to 19), user defined modes (20 to 29)
SAMPLE files 99 files
(SAMPLE No., ID code, MASTER file and sample amount)
Automatic input function Automatic input of blank, factors, concentration measurement results, etc.
Calculation functions Concentration calculation, statistics calculation, pH automatic compensation
Memory data capacity 100 data (titration results, titration parameters) When memory card (32MB) is used, approximately 1200 data can be stored.
GLP functions Buret precision check, electrode check, buret use frequency, electrode maintenance, remaining reagent volume
Buret Up to 10 burets connected, buret capacity 20 mL (1, 5, 10, and 50 mL are optional.)
Printer interface One port standard
(PR-2000T2, PR-302B or LIPS III-type A4-size printer) Note 1
External 
input/output
RS-232C communication port
(for balance input or computer connection)
Expansion bus Expansion bus for full-automatic titration system
Power requirements 100 V to 240 V AC, 50/60 Hz, 60 VA
Dimensions 220 mm(W) x 400 mm (D) x 200 (H) mm
Mass Approx. 5.0 kg
Attached electrodes · GE-101B Glass combination electrode
· RE-201 Reference electrode
 
  Note 1: Some A4-size printers cannot be connected to this equipment.
Please contact us and check.
 
 B-2000-20 Standard Specifications
 
Item Specifications
Buret capacity Standard: 20 mL, clear cylinder (with ultraviolet
interception protective cover) The buret heads of 1, 5, 10, and 50 mL are exchangeable (option).
Fabrication 5, 10, 20, and 50 mL: The inner cylinder is fabricated through precision grinding.
1 mL: The outer cylinder is fabricated through precision grinding 1 and 50 mL cylinders are brown.
5, 10, and 20 mL cylinders are clear (with ultraviolet interception protective cover)
Wet path material Teflon, hard glass, and ceramic
Connection tube 2 x 3 mm, brown Teflon tube
Reagent bottle Brown glass bottle, 1 L
Selector valve Automatic selection by way of a ground ceramic joint
Dispensing rate
(full capacity)
50 to 250 seconds, specified by 50 second step (for 20 mL buret)
Smallest volume of
titrant
0.00125 mL when a 20 mL buret is used
Buret precision Accuracy: within ±0.1 %
(for full discharge of 20 mL buret)
Repeatability: within 0.01 mL (for full discharge of 20 mL buret, standard deviation for n = 5)
Power requirements 100 V to 240 V AC, 50/60 Hz, 50 VA
Dimensions 122 mm(W) x 280 mm (D) x 475 (H) mm
Mass Approx. 7.0 kg
 
 K-2000T2 Standard Specifications
 
Item Specifications
Number of the equipment to an electrode holder Electrode (cap size 16 mm) ; 2 places
Thermistor electrode (cap size 10 mm) ; 1 place 
Buret tip ; 3 places
Dispenser tip ; 1 place
Beaker Up to 500 mL
Stirring method With the aid of a magnetic flea
Stirring piece Teflon ( 8 x 30 mm, 1 piece supplied)
Power requirements DC 12V (supplied from COM-1600)
Dimensions 110 mm(W) x 210 mm (D) x 350 (H) mm
Mass Approx. 1.0 kg
 
   S-2000 Standard Specifications
 
Item Specifications
Number of inputs Inputs for potentiometric titration: 3
Input for temperature compensation: 1
Detection range pH: 0 to 14 pH (automatic/manual temperature compensation)
Potential: -2000 to +2000 mV
Temperature: 0 to 100
Power requirements DC 12V (supplied from COM-1600)
Dimensions 50 mm(W) x 80 mm (D) x 125 (H) mm
Mass Approx. 0.3 kg
 
  PR-2000T2 Standard Specifications
 
Item Specifications
Printing method/paper Thermal head type, thermal roll paper
(chart width: 80 mm)
Power requirements 100 V to 240 V AC, 50/60 Hz (with AC adapter)
Dimensions 119 mm(W) x 174 mm (D) x 77 (H) mm
Mass Approx. 0.5 kg (printer main unit only)
 

Tinggalkan Balasan

Isikan data di bawah atau klik salah satu ikon untuk log in:

Logo WordPress.com

You are commenting using your WordPress.com account. Logout / Ubah )

Gambar Twitter

You are commenting using your Twitter account. Logout / Ubah )

Foto Facebook

You are commenting using your Facebook account. Logout / Ubah )

Foto Google+

You are commenting using your Google+ account. Logout / Ubah )

Connecting to %s

%d blogger menyukai ini: