HYDRA C APPENDIX K

New Hydra-C Mercury Analysis System for Appendix K
Hydra C Mercury Analysis System for Appendix K Teledyne Leeman Labs is pleased to announce the introduction of a new mercury analyzer for emissions monitoring, the Hydra-C Appendix K

The EPA clean air mercury rule requires coal fired power generation facilities to monitor mercury emissions on a continuous basis. This can be achieved either through the installation of continuous emission monitors (CEM) or by the use of sorbent trap technology, where emitted mercury is trapped on a sorbent material and analyzed by a suitable method. (Appendix K)

The new Hydra-C Appendix K system has been designed to be compliant with CFR40, Part 75, Appendix K (Sorbent trap analysis method).

Some of Hydra-C’s Appendix K features include:

  • Easy-to-use, combustion technology: No messy digestion procedures required
  • Fully automated analysis: User friendly software guides the user through setup for multi-sample unattended analysis
  • 70 position autosampler: Fully automated analysis of up to 70 samples
  • Analysis of both daily and weekly sorbent traps: Versatile detection system offers an extended dynamic range.
  • RATA testing: Compliant with all Relative Accuracy Test Audit requirements
  • Analysis of coal and fly ash: System can be applied to a wide variety of  analytical needs and sample types.
  • Automated scheduled maintenance: Tracks system usage and instructs the operator when maintenance is recommended
  • Fast and economical service: The unit has been designed using a modular  approach allowing the simple exchange of key components
  • Pedigree in Hg analysis: Teledyne Leeman Labs has been a leading supplier of instrumentation for the analysis of mercury for over 15 years.
 

Satu Tanggapan to “HYDRA C APPENDIX K”

  1. MERCURY ANALYZER « Says:

    […] Hydra C – Appendix K The new Hydra-C Appendix K system has been designed to be compliant with CFR40, Part 75, Appendix K (Sorbent trap analysis method). Ditulis dalam MERCURY ANALYZER. Tag: Hg, Mercury, MERCURY ANALYZER, TELEDYNE LEEMAN. […]


Tinggalkan Balasan

Isikan data di bawah atau klik salah satu ikon untuk log in:

Logo WordPress.com

You are commenting using your WordPress.com account. Logout / Ubah )

Gambar Twitter

You are commenting using your Twitter account. Logout / Ubah )

Foto Facebook

You are commenting using your Facebook account. Logout / Ubah )

Foto Google+

You are commenting using your Google+ account. Logout / Ubah )

Connecting to %s

%d blogger menyukai ini: